Loading...

Proceedings of

4th International Conference On Advances in Applied Science and Environmental Engineering ASEE 2015

"CONTINUOUS-FLOW DISINFECTION REACTOR FOR DRINKING WATER USING GEL-DERIVED AG-TIO2-SIO2 CATALYST UNDER UV-C LIGHT"

HOANG-ANH HUA KHOI TRAN-TIEN NHUNG THI-TUYET HOANG THE-VINH NGUYEN
DOI
10.15224/978-1-63248-055-2-76
Pages
118 - 123
Authors
4
ISBN
978-1-63248-068-2

Abstract: “Clean water for drinking and cooking has been a serious issue in rural areas of Vietnam, which is mainly due to high-cost treatment of the available water sources in such areas. In order to decrease the treatment cost, gel-derived Ag-TiO2-SiO2 thin film coated on glass beads were used as disinfection materials under UV-C light in this work. The photocatalyst was used in a continuous-flow lab-scale reactor to disinfect E.coli in water. It was found that the bactericidal activity of this system using the gel-derived Ag-TiO2-SiO2 photoatalyst under UV-C irradiation was superior to those using UV-C irradiation alone, a combination of bare glass beads and UV-C irradiation. By using gel-derived Ag-TiO2-SiO2thin film, the above reactor was observed to remove 6-log of E.coli under UV-C within the hydraulic retention time of 6 minutes.The reactor was also operated with Mekong river water (includes Tien river and Hau river) with the inlet microbial loading of Tien river (after filtering) from 50”

Keywords: gel-derived Ag-TiO2-SiO2; E.colidisinfection; UVC lamp; continuous-flow reactor

Download PDF